貴(gui)州(zhou)HDPE雙(shuang)壁波紋管(guan)怎樣做到有效施工
貴州HDPE雙壁波紋管在施工過程中一定要有所講究,不然容易出問題,影響工程進度,下面,大家就一起來看看都有哪些注意事項:
1、嚴禁拋擲(zhi)、拖滾(gun)和相互撞擊
管(guan)材(cai)如(ru)長(chang)時間(jian)存(cun)放(fang)(fang),應(ying)置于(yu)棚庫內。當(dang)露天堆(dui)放(fang)(fang)時,必須(xu)加以遮蓋,防治暴曬,并遠(yuan)離熱(re)源(yuan)。管(guan)材(cai)存(cun)放(fang)(fang)時間(jian)不(bu)(bu)宜大于(yu)12個(ge)月(yue)。超(chao)過12個(ge)月(yue)的管(guan)材(cai),使用(yong)時應(ying)重新檢測,檢測不(bu)(bu)合格的不(bu)(bu)得使用(yong)。管(guan)材(cai)堆(dui)放(fang)(fang)高度不(bu)(bu)宜過高,防止下層(ceng)管(guan)材(cai)受壓變形。
2、管(guan)道溝槽(cao)的開挖斷面應(ying)符(fu)合(he)要求
槽(cao)底(di)原狀地(di)基土不(bu)得擾動,機械開(kai)挖(wa)(wa)槽(cao)底(di)預留200~300mm土層由(you)人工(gong)開(kai)挖(wa)(wa)至設(she)計標高并整平;溝槽(cao)底(di)嚴禁受水浸泡(pao)或受凍,否則應(ying)進行地(di)基加固(gu)處理。管(guan)道連接前,應先(xian)檢(jian)驗膠圈(quan)(quan)是否配套完好,由管(guan)材生產廠家配套供應。所選用(yong)的橡膠圈(quan)(quan)外觀應平整光滑,不允許有氣孔、裂縫(feng)、卷皺、破損、重皮等缺陷。
確認膠圈(quan)安(an)(an)放位置準(zhun)確,橡膠圈(quan)安(an)(an)裝的正確位置應在(zai)(zai)接(jie)口(kou)(kou)第二道(dao)與(yu)第三(san)道(dao)波紋之間(jian),安(an)(an)裝橡膠圈(quan)的數量視設計要求而定,當采用兩(liang)只橡膠圈(quan)時,建議(yi)兩(liang)橡膠圈(quan)之間(jian)隔一個波紋;接(jie)口(kou)(kou)作(zuo)業時,應先(xian)將承(cheng)口(kou)(kou)的內工作(zuo)面(mian)(mian)及插(cha)口(kou)(kou)外(wai)工作(zuo)面(mian)(mian)清(qing)理干凈(jing),嚴禁有泥土等雜物,并在(zai)(zai)承(cheng)口(kou)(kou)內工作(zuo)面(mian)(mian)和(he)橡膠圈(quan)表面(mian)(mian)涂上潤滑(hua)劑(一般用肥皂水即可(ke))。
按插入(ru)(ru)方(fang)向為水流方(fang)向,可(ke)在(zai)管(guan)(guan)子(zi)端部設置(zhi)木擋板,用撬棍(gun)使被安(an)裝(zhuang)的(de)管(guan)(guan)道沿著對(dui)準的(de)軸線徐徐的(de)插入(ru)(ru)承口(kou)內,逐節依次安(an)裝(zhuang)。管(guan)(guan)徑≥400ram的(de)管(guan)(guan)道可(ke)用柔性纜繩系住(zhu)管(guan)(guan)道,用手動(dong)葫蘆等提力工(gong)具,嚴禁用施工(gong)機械強行推頂管(guan)(guan)道插入(ru)(ru)承口(kou)。安(an)裝(zhuang)完成后,檢查關鍵插口(kou)插入(ru)(ru)是否到位(wei)。
3、檢查(cha)井砌筑(zhu)關
檢(jian)查井的基(ji)礎(chu)應建在(zai)原(yuan)狀(zhuang)土上,當原(yuan)狀(zhuang)土地(di)基(ji)松(song)軟或(huo)被擾(rao)動時(shi),應按設計及規范要求(qiu)進行地(di)基(ji)處理;檢(jian)查井混凝土基(ji)礎(chu)應與管道基(ji)礎(chu)同(tong)事澆注(zhu),防止管道與檢(jian)查井不(bu)均勻沉降(jiang);檢(jian)查井砌(qi)(qi)筑前砌(qi)(qi)塊應充分濕潤,砌(qi)(qi)筑時(shi)HDPE雙壁波(bo)紋(wen)管外壁水(shui)泥(ni)沙漿座漿應飽滿、密實。
檢(jian)查井(jing)(jing)砌(qi)筑時,砌(qi)筑水泥砂(sha)漿(jiang)(jiang)強度(du)應(ying)(ying)(ying)(ying)符合(he)(he)設計要求,鋪漿(jiang)(jiang)應(ying)(ying)(ying)(ying)飽滿,灰(hui)漿(jiang)(jiang)與(yu)砌(qi)塊(kuai)四周粘接(jie)應(ying)(ying)(ying)(ying)緊密、嚴(yan)禁漏漿(jiang)(jiang),上下砌(qi)塊(kuai)應(ying)(ying)(ying)(ying)錯縫砌(qi)筑;有支、連管(guan)接(jie)入的(de)(de)檢(jian)查井(jing)(jing)井(jing)(jing)室(shi),應(ying)(ying)(ying)(ying)在井(jing)(jing)室(shi)施(shi)工(gong)的(de)(de)同時安(an)裝(zhuang)預(yu)留(liu)支、連管(guan),預(yu)留(liu)管(guan)的(de)(de)管(guan)徑、方向(xiang)、高程應(ying)(ying)(ying)(ying)符合(he)(he)設計及規范要求,管(guan)與(yu)井(jing)(jing)壁銜接(jie)處應(ying)(ying)(ying)(ying)嚴(yan)密;檢(jian)查井(jing)(jing)的(de)(de)預(yu)留(liu)管(guan)管(guan)口應(ying)(ying)(ying)(ying)采用低強度(du)砂(sha)漿(jiang)(jiang)砌(qi)筑封口抹(mo)平;井(jing)(jing)壁抹(mo)面應(ying)(ying)(ying)(ying)密實平整,嚴(yan)禁有空鼓、裂縫等現(xian)象。
4、閉水(shui)試驗(yan)關
管(guan)道施(shi)工結(jie)束應及(ji)(ji)時進行閉(bi)水試(shi)驗。閉(bi)水試(shi)驗前管(guan)道及(ji)(ji)檢查井外觀質量應經驗收合格且管(guan)道未回填、溝槽內(nei)無(wu)積水,全(quan)部預留(liu)孔(kong)應封堵(du),不得滲水。
管(guan)道閉(bi)水(shui)(shui)(shui)試(shi)驗(yan)(yan)時(shi)試(shi)驗(yan)(yan)段(duan)上(shang)游(you)(you)設(she)計(ji)水(shui)(shui)(shui)頭(tou)(tou)(tou)應不超(chao)過(guo)管(guan)頂(ding)內(nei)壁(bi)時(shi),試(shi)驗(yan)(yan)水(shui)(shui)(shui)頭(tou)(tou)(tou)應以試(shi)驗(yan)(yan)上(shang)游(you)(you)管(guan)頂(ding)內(nei)壁(bi)加(jia)2m計(ji),試(shi)驗(yan)(yan)段(duan)上(shang)游(you)(you)設(she)計(ji)水(shui)(shui)(shui)頭(tou)(tou)(tou)超(chao)過(guo)管(guan)頂(ding)內(nei)壁(bi)時(shi),試(shi)驗(yan)(yan)水(shui)(shui)(shui)頭(tou)(tou)(tou)應以試(shi)驗(yan)(yan)段(duan)上(shang)游(you)(you)設(she)計(ji)水(shui)(shui)(shui)頭(tou)(tou)(tou)加(jia)2m計(ji),計(ji)算處的試(shi)驗(yan)(yan)水(shui)(shui)(shui)頭(tou)(tou)(tou)小(xiao)于10m,但(dan)已超(chao)過(guo)上(shang)游(you)(you)檢(jian)查(cha)井井口時(shi),試(shi)驗(yan)(yan)水(shui)(shui)(shui)頭(tou)(tou)(tou)應以上(shang)游(you)(you)檢(jian)查(cha)井井口高度為(wei)準。
管(guan)道(dao)閉水(shui)試(shi)驗時(shi),應(ying)(ying)進行外觀(guan)檢查(cha),嚴(yan)禁有(you)漏(lou)水(shui)現象,當水(shui)頭(tou)達(da)到要求高度時(shi),檢查(cha)磚堵、管(guan)身、井身,有(you)無漏(lou)水(shui),如有(you)嚴(yan)重滲(shen)漏(lou)應(ying)(ying)進行封堵。待浸泡24h后,再觀(guan)察滲(shen)水(shui)量,對滲(shen)水(shui)量的(de)測定(ding)時(shi)間(jian)不應(ying)(ying)少于(yu)30min。正確(que)計算滲(shen)水(shui)量,實測滲(shen)水(shui)量應(ying)(ying)小于(yu)或等于(yu)《給水(shui)排水(shui)管(guan)道(dao)施(shi)工及(ji)驗收規范》 (GB50268—2008)規定(ding)的(de)允許滲(shen)水(shui)量。
5、回天了(le)質量控制關
管道(dao)閉(bi)水(shui)試驗合格后,應及時回填(tian),回填(tian)前應檢(jian)查管道(dao)有(you)無損傷或變形,有(you)損傷的管道(dao)應修復或更換(huan);管道(dao)溝槽(cao)回填(tian)時溝槽(cao)內(nei)不得(de)有(you)磚(zhuan)、石、木塊等雜物,溝槽(cao)內(nei)嚴禁有(you)積水(shui),嚴禁帶水(shui)回填(tian)。
回(hui)填(tian)(tian)土(tu)(tu)土(tu)(tu)質應(ying)符合(he)設計(ji)及(ji)規(gui)范(fan)(fan)要求,槽底至管頂以上500ram范(fan)(fan)圍內,回(hui)填(tian)(tian)土(tu)(tu)不得含有有機(ji)物、凍土(tu)(tu)及(ji)大于50ram的碎磚、石塊(kuai)、混凝土(tu)(tu)碎塊(kuai)等雜物;回(hui)填(tian)(tian)土(tu)(tu)的含水量應(ying)按土(tu)(tu)類和采(cai)用(yong)的壓實工具控制在最佳含水率(lv)±2%范(fan)(fan)圍內:管道(dao)有效支(zhi)撐角(jiao)范(fan)(fan)圍應(ying)采(cai)用(yong)中粗砂填(tian)(tian)充(chong)密(mi)實,與管壁緊密(mi)接觸,不能用(yong)土(tu)(tu)或其他材料(liao)填(tian)(tian)充(chong)。
貴州HDPE管道生產,管道兩側和管頂以上500mm范圍內的回填材料,應由溝槽兩側對稱運人槽內,嚴禁直接回填在管道上,其他部位回填時,應均勻運入槽內,嚴禁集中推入;管道半徑以下回填時應采取防止管道上浮、位移的措施;管道回填時應從管道兩側分層對稱回填、同時夯實,每層回填土的虛鋪厚度應根據《給水排水管道工程施工及驗收規范》 (GB50236—2008)執行。